{"product_id":"uni-t-ut275-clamp-earth-resistance-tester","title":"UNI-T Clamp Earth Resistance Tester, 0.01–1000 Ω, 30 A – UT275","description":"\u003cp\u003eThe UNI-T UT275 is a clamp earth resistance tester for measuring grounding resistance from 0.01 to 1000Ω and leakage current up to 30A. Its 28mm clamp jaw enables grounding-system checks without disconnecting ground lines or using auxiliary electrodes.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eClamp measurement of earth ground resistance from 0.01 to 1000Ω\u003c\/li\u003e\n\u003cli\u003eLeakage current measurement up to 30A\u003c\/li\u003e\n\u003cli\u003e28mm jaw opening for conductors and grounding connections\u003c\/li\u003e\n\u003cli\u003eResistance limit alarm, automatic range and automatic calibration\u003c\/li\u003e\n\u003cli\u003eData hold, data recall, backlight, low-battery indication and 30-set data storage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eClamp Earth Resistance Tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eUT275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eLCD, 10000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eJaw Opening\u003c\/th\u003e\n\u003ctd\u003e28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eData Storage\u003c\/th\u003e\n\u003ctd\u003e30 sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003e1.5V LR6 batteries × 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Dimensions\u003c\/th\u003e\n\u003ctd\u003e293 × 90 × 66 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNet Weight\u003c\/th\u003e\n\u003ctd\u003e1.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eMeasurement Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth Ground Resistance\u003c\/td\u003e\n\u003ctd\u003e0.01–0.099Ω\u003c\/td\u003e\n\u003ctd\u003e±(1% + 0.01Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth Ground Resistance\u003c\/td\u003e\n\u003ctd\u003e0.1–0.99Ω\u003c\/td\u003e\n\u003ctd\u003e±(1% + 0.01Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth Ground Resistance\u003c\/td\u003e\n\u003ctd\u003e1–49.9Ω\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 0.1Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth Ground Resistance\u003c\/td\u003e\n\u003ctd\u003e50–99.5Ω\u003c\/td\u003e\n\u003ctd\u003e±(2% + 0.5Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth Ground Resistance\u003c\/td\u003e\n\u003ctd\u003e100–199Ω\u003c\/td\u003e\n\u003ctd\u003e±(3% + 1Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth Ground Resistance\u003c\/td\u003e\n\u003ctd\u003e200–395Ω\u003c\/td\u003e\n\u003ctd\u003e±(10% + 5Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth Ground Resistance\u003c\/td\u003e\n\u003ctd\u003e400–590Ω\u003c\/td\u003e\n\u003ctd\u003e±(20% + 10Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth Ground Resistance\u003c\/td\u003e\n\u003ctd\u003e600–1000Ω\u003c\/td\u003e\n\u003ctd\u003e±(25% + 20Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003e0–299mA\u003c\/td\u003e\n\u003ctd\u003e±(2.5% + 2mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003e0.3–2.99A\u003c\/td\u003e\n\u003ctd\u003e±(2.5% + 100mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003e3–30A\u003c\/td\u003e\n\u003ctd\u003e±(2.5% + 300mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGrounding-system inspection\u003c\/li\u003e\n\u003cli\u003eElectrical installation maintenance\u003c\/li\u003e\n\u003cli\u003eTelecommunications and equipment-room testing\u003c\/li\u003e\n\u003cli\u003ePower distribution and industrial grounding checks\u003c\/li\u003e\n\u003cli\u003eLightning-protection and grounding continuity inspection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIncluded Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUT275 clamp earth resistance tester\u003c\/li\u003e\n\u003cli\u003e1.5V LR6 batteries × 4\u003c\/li\u003e\n\u003cli\u003eTest ring\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003cli\u003eGift box and tool box\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"UNI-T","offers":[{"title":"UT275","offer_id":58854977012037,"sku":"003152","price":408.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/99700713-43de-421d-bf1b-683021bf12ec.jpg?v=1786589084","url":"https:\/\/www.periplusmro.com\/products\/uni-t-ut275-clamp-earth-resistance-tester","provider":"PERIPLUS MRO SHOP","version":"1.0","type":"link"}