{"product_id":"uni-t-ut51-digital-multimeter","title":"UNI-T Digital Multimeter, 1000 V DC\/750 V AC, 10 A AC\/DC, 200 MΩ – UT51","description":"\u003cp\u003eThe UNI-T UT51 is a general-purpose manual-range digital multimeter for measuring AC\/DC voltage, AC\/DC current and resistance. It also supports diode, transistor and continuity testing, making it suitable for electronics repair, electrical maintenance, manufacturing and HVAC service work.\u003c\/p\u003e\n\u003cdiv style=\"font-family: Helvetica, Arial, sans-serif; color: #000000; font-size: 12pt; line-height: 1.5;\"\u003e\n\u003ch2 style=\"font-size: 14pt;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures AC\/DC voltage, AC\/DC current and resistance\u003c\/li\u003e\n\u003cli\u003eManual range selection with a 1999-count, 3½-digit display\u003c\/li\u003e\n\u003cli\u003eMeasures DC voltage up to 1000V and AC voltage up to 750V\u003c\/li\u003e\n\u003cli\u003eMeasures AC\/DC current up to 10A and resistance up to 200MΩ\u003c\/li\u003e\n\u003cli\u003eIncludes diode, transistor and audible continuity testing functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt;\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; font-size: 12pt;\" border=\"1\" cellspacing=\"0\" cellpadding=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f5f5f5;\"\u003e\n\u003cth style=\"text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eUNI-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eUT50 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUT51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange Selection\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Measurement Type\u003c\/td\u003e\n\u003ctd\u003eAverage responding; calibrated to the RMS value of a sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Display\u003c\/td\u003e\n\u003ctd\u003e1999 counts, 3½ digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage Ranges\u003c\/td\u003e\n\u003ctd\u003e200mV, 2V, 20V, 200V and 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage Basic Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.5% of reading + 1 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Ranges\u003c\/td\u003e\n\u003ctd\u003e200mV, 2V, 20V, 200V and 750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Basic Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.8% of reading + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Frequency Range\u003c\/td\u003e\n\u003ctd\u003e40–400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Impedance\u003c\/td\u003e\n\u003ctd\u003e10MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current Ranges\u003c\/td\u003e\n\u003ctd\u003e20µA, 200µA, 2mA, 20mA, 200mA, 2A and 10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current Basic Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.8% of reading + 1 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current Ranges\u003c\/td\u003e\n\u003ctd\u003e200µA, 2mA, 20mA, 200mA, 2A and 10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current Basic Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% of reading + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Input\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Current Measurement Duration\u003c\/td\u003e\n\u003ctd\u003eLess than 10 seconds, with at least 15 minutes between measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Ranges\u003c\/td\u003e\n\u003ctd\u003e200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ, 20MΩ and 200MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Basic Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.8% of reading + 1 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Test\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Test\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Continuity Test\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow-Battery Indication\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eFull-range overload protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Fuse Protection\u003c\/td\u003e\n\u003ctd\u003e2A\/250V fuse for ranges below 2A; 10A\/250V fuse for the 10A range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e65 × 33mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigit Height\u003c\/td\u003e\n\u003ctd\u003e27mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003e0°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Altitude\u003c\/td\u003e\n\u003ctd\u003e2,000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e1 × 9V 6F22 battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Dimensions\u003c\/td\u003e\n\u003ctd\u003e190 × 88 × 34mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003eApproximately 540g including protective holster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Colour\u003c\/td\u003e\n\u003ctd\u003eRed and grey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standard\u003c\/td\u003e\n\u003ctd\u003eIEC 61010; CAT I 1000V, CAT II 600V and CAT III 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 14pt;\"\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical and electronic equipment troubleshooting\u003c\/li\u003e\n\u003cli\u003eElectronic repair and circuit testing\u003c\/li\u003e\n\u003cli\u003eManufacturing and production maintenance\u003c\/li\u003e\n\u003cli\u003eHVAC equipment inspection and field service\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt;\"\u003eIncluded Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × UNI-T UT51 Digital Multimeter\u003c\/li\u003e\n\u003cli\u003e1 × Pair of Test Leads\u003c\/li\u003e\n\u003cli\u003e1 × 9V 6F22 Battery\u003c\/li\u003e\n\u003cli\u003e1 × Protective Holster\u003c\/li\u003e\n\u003cli\u003e1 × English User Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"UT51","offer_id":58730083025221,"sku":"003088","price":9302.4,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/d66509fd-f984-49b8-9a10-a75fa4ff5f2c.jpg?v=1785495572","url":"https:\/\/www.periplusmro.com\/en-hu\/products\/uni-t-ut51-digital-multimeter","provider":"PERIPLUS MRO SHOP","version":"1.0","type":"link"}