{"product_id":"uni-t-ut505a-1kv-handheld-insulation-resistance-tester","title":"UNI-T True RMS Insulation Resistance Tester, 50-1000 V, 20 GΩ, PI \u0026 DAR – UT505A","description":"The UNI-T UT505A is a handheld True RMS insulation resistance tester offering five test voltages up to 1kV and measurements up to 20GΩ. It combines insulation testing with AC\/DC voltage and low-resistance measurement for electrical installation, maintenance and equipment diagnostics.\u003cdiv style=\"font-family: Helvetica, Arial, sans-serif; color: #000000; font-size: 12pt; line-height: 1.5;\"\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 0 0 10px 0;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eFive selectable insulation test voltages from 50V to 1000V\u003c\/li\u003e\n\u003cli\u003eMeasures insulation resistance from 0.01MΩ up to 20GΩ\u003c\/li\u003e\n\u003cli\u003ePI and DAR measurements for evaluating insulation condition\u003c\/li\u003e\n\u003cli\u003eTrue RMS AC\/DC voltage measurement with a 6000-count display\u003c\/li\u003e\n\u003cli\u003eAutomatic discharge, high-voltage warning and live-circuit detection for safer operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 12pt;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 40%; border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUNI-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUT505A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eInstrument Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eHandheld True RMS insulation resistance tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eInsulation Test Voltages\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e50V, 100V, 250V, 500V and 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTest Voltage Adjustment\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e50% to 120% of selected range in 10% steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eInsulation Resistance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e0.01MΩ to 20GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e50V Test Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e0.01MΩ to 50MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e100V Test Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e0.01MΩ to 100MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e250V Test Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e0.01MΩ to 200MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e500V Test Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e0.01MΩ to 500MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e1000V Test Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e0.1MΩ to 20GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eShort-Circuit Current\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eLess than 2mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eLow-Resistance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e0.01Ω to 20.00kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e0.0V to 600.0V, True RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e0.0V to 600.0V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eInsulation Diagnostic Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003ePolarisation Index (PI) and Dielectric Absorption Ratio (DAR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTimed testing, comparison function, data hold and automatic ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eData Storage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e99 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e6000-count backlit LCD with analogue bar graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eSafety Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAutomatic discharge, high-voltage warning and live-circuit warning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eIEC 61557-1, IEC 61557-2 and IEC 61557-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e6 × 1.5V AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e225 × 103 × 59mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eApproximately 630g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eMotor and generator winding insulation testing\u003c\/li\u003e\n\u003cli\u003eElectrical cable and wiring insulation inspection\u003c\/li\u003e\n\u003cli\u003eTransformer, switchgear and electrical panel maintenance\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance of industrial electrical equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eIncluded Components\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eUNI-T UT505A insulation resistance tester\u003c\/li\u003e\n\u003cli\u003eTest leads and test probes\u003c\/li\u003e\n\u003cli\u003eAlligator clips\u003c\/li\u003e\n\u003cli\u003e6 × 1.5V AA batteries\u003c\/li\u003e\n\u003cli\u003eCarrying bag and user documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"UT505A","offer_id":58761603744069,"sku":"003113","price":63415.77,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/cea1a9b0-87c8-4b17-af94-0257dc6daf5a.jpg?v=1785826668","url":"https:\/\/www.periplusmro.com\/en-hu\/products\/uni-t-ut505a-1kv-handheld-insulation-resistance-tester","provider":"PERIPLUS MRO SHOP","version":"1.0","type":"link"}