{"product_id":"uni-t-ut216b-600a-true-rms-ac-clamp-meter","title":"UNI-T True RMS AC Clamp Meter, 600 A, 6000 Counts, VFC \u0026 NCV – UT216B","description":"The UNI-T UT216B is a True RMS digital clamp meter for measuring alternating current up to 600A with a 40–400Hz frequency response. Its VFC low-pass filter and frequency measurement functions make it suitable for variable-frequency drives, power systems and industrial electrical maintenance.\u003cdiv style=\"font-family: Helvetica, Arial, sans-serif; color: #000000; font-size: 12pt; line-height: 1.5;\"\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 0 0 10px 0;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eMeasures alternating current up to 600A with a 40–400Hz frequency response\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement for non-sinusoidal and variable-frequency signals\u003c\/li\u003e\n\u003cli\u003eVFC low-pass filter helps reduce high-frequency interference during drive measurements\u003c\/li\u003e\n\u003cli\u003eMeasures AC\/DC voltage, resistance, capacitance and frequency\u003c\/li\u003e\n\u003cli\u003eNCV detection, maximum\/minimum, relative and data-hold functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 12pt;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 40%; border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUNI-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUT216B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMeter Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTrue RMS digital AC clamp meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e6A \/ 60A \/ 600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to ±(2.5% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Frequency Response\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e40Hz to 400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Current Measurement\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Frequency Response\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e40Hz to 400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eResistance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 60MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 60mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eFrequency Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e10Hz to 1MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDisplay Count\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e6000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eSampling Rate\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eApproximately 3 readings per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMeasurement Response\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTrue RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eJaw Opening\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eRanging\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eLow-Pass Filter\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eVFC mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eVoltage Detection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNCV non-contact AC voltage detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Test Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDiode test and audible continuity test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMaximum\/minimum values, relative mode, data hold, LCD backlight, work light and automatic power-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e≥10MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCE, UKCA and cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e3 × 1.5V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDisplay Size\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e38 × 24mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e220 × 75 × 40mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eApproximately 232g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eVariable-frequency drive and motor-system testing\u003c\/li\u003e\n\u003cli\u003eServer room, data centre and power-supply maintenance\u003c\/li\u003e\n\u003cli\u003eElectrical distribution and control-panel inspection\u003c\/li\u003e\n\u003cli\u003eIndustrial electrical equipment troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eIncluded Components\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eUNI-T UT216B True RMS AC clamp meter\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003e3 × 1.5V AAA batteries\u003c\/li\u003e\n\u003cli\u003eCarrying bag and user documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"UT216B","offer_id":58761605808453,"sku":"003120","price":24936.16,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/c8adc508-a1b9-4f98-a611-acc2aac4390d.jpg?v=1785826707","url":"https:\/\/www.periplusmro.com\/en-hu\/products\/uni-t-ut216b-600a-true-rms-ac-clamp-meter","provider":"PERIPLUS MRO SHOP","version":"1.0","type":"link"}