{"product_id":"uni-t-ut213b-400a-true-rms-ac-clamp-meter","title":"UNI-T True RMS AC Clamp Meter, 400 A, 4000 Counts, Temperature \u0026 NCV – UT213B","description":"The UNI-T UT213B is a True RMS digital clamp meter for measuring alternating current up to 400A through a 30mm jaw. It also provides voltage, resistance, capacitance, frequency and temperature measurement for electrical, HVAC\/R and industrial maintenance work.\u003cdiv style=\"font-family: Helvetica, Arial, sans-serif; color: #000000; font-size: 12pt; line-height: 1.5;\"\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 0 0 10px 0;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eMeasures alternating current up to 400A through a 30mm jaw\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement for improved accuracy on non-sinusoidal signals\u003c\/li\u003e\n\u003cli\u003eMeasures AC\/DC voltage, resistance, capacitance, frequency and temperature\u003c\/li\u003e\n\u003cli\u003eNon-contact voltage detection for identifying energised conductors\u003c\/li\u003e\n\u003cli\u003eMaximum\/minimum, relative and data-hold functions for measurement analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 12pt;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 40%; border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUNI-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUT213B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMeter Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTrue RMS digital AC clamp meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(1.8% + 9 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Current Measurement\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(1.2% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Voltage Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(0.8% + 1 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eResistance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 40MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 40mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eFrequency Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e10Hz to 1MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e-40°C to 1000°C \/ -40°F to 1832°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDisplay Count\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e4000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMeasurement Response\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTrue RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eJaw Opening\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eRanging\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eVoltage Detection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNCV non-contact voltage detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Test Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDiode test and audible continuity test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMaximum\/minimum values, relative mode, data hold, LCD backlight, work light and automatic power-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e≥10MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eSafety Category\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCAT III 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCE, UKCA and cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e3 × 1.5V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e220 × 75 × 40mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eApproximately 280g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eElectrical installation inspection and troubleshooting\u003c\/li\u003e\n\u003cli\u003eHVAC\/R electrical and temperature measurements\u003c\/li\u003e\n\u003cli\u003eMotor, distribution-board and electrical panel maintenance\u003c\/li\u003e\n\u003cli\u003eCommercial and light-industrial equipment servicing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eIncluded Components\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eUNI-T UT213B True RMS AC clamp meter\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003ePoint-contact temperature probe\u003c\/li\u003e\n\u003cli\u003e3 × 1.5V AAA batteries\u003c\/li\u003e\n\u003cli\u003eCarrying bag and user documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"UT213B","offer_id":58761604759877,"sku":"003117","price":16827.16,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/f283bd67-c651-40fe-a77b-f9810e363b77.jpg?v=1785826689","url":"https:\/\/www.periplusmro.com\/en-hu\/products\/uni-t-ut213b-400a-true-rms-ac-clamp-meter","provider":"PERIPLUS MRO SHOP","version":"1.0","type":"link"}