{"title":"Digital Multimeters","description":"\u003cp data-start=\"0\" data-end=\"367\"\u003eShop digital multimeters for electrical testing, troubleshooting, and maintenance. Measure voltage, current, resistance, continuity, capacitance, and more with reliable handheld meters for MRO, workshop, and field use.\u003c\/p\u003e","products":[{"product_id":"clamp-multimeter-true-rms-ac-dc-600a-ncv-yato-yt-730934","title":"CLAMP MULTIMETER, TRUE RMS AC\/DC 10 mA–600 A;YT-730934","description":"\u003cp\u003eThe universal clamp meter with automatic range for each measurement allows you to perform basic and advanced measurements of electrical quantities. The meter is equipped with measuring clamps that allow to measure DC as well as AC current in a single wire by means of a built-in HALL sensor. The measurement is carried out without disconnecting the circuit or disconnecting it from the power source, and makes it possible to measure much higher current than conventional electric meters. The leads of the measuring probes have silicone insulation, which is flexible and resistant to high temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/0-60_mF.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/0-60_M-OMEGA.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/0-300_kHz.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/0-600A_AC.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/0-600A_DC.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/0-600V_AC.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/0-600V_DC.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/AAA_2x_a3f76caf-6766-4a28-b891-fa0981af447c.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/AUTO_POWER_OFF_ENG.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/AUTO_RANGE_ENG.png?v=1779199892\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/BUZZER.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/DATA_HOLD.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/DIODE.png?v=1779199892\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/FRONT_LIGHT_ENG.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/LCD_6000.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/LED_BACKLIGHT_ENG.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/NCV.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/PEAK_HOLD.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/TEMP_-30__2B1000_C.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/TEST_INDUCTION.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/TRUE_RMS.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGENERAL\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct name\u003c\/td\u003e\n\u003ctd\u003eClamp Multimeter, TRUE RMS AC\/DC 10 mA–600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand \/ Index\u003c\/td\u003e\n\u003ctd\u003eYATO \/ YT-730934\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit of measure\u003c\/td\u003e\n\u003ctd\u003ePCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSIZE \u0026amp; CLAMP\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185 × 65 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax cable diameter (clamp)\u003c\/td\u003e\n\u003ctd\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax clamp gap\u003c\/td\u003e\n\u003ctd\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDISPLAY \u0026amp; FEATURES\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay type\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e6000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED backlight\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront lighting\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTRUE RMS\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNCV (Non-contact AC voltage detection)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak value hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto measurement range\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling frequency\u003c\/td\u003e\n\u003ctd\u003e3 times per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto power off\u003c\/td\u003e\n\u003ctd\u003e15 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow battery indicator\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMEASUREMENT RANGES\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC voltage\u003c\/td\u003e\n\u003ctd\u003e0–600 V a.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e0–600 V d.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current (clamp)\u003c\/td\u003e\n\u003ctd\u003e0–600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC current (clamp)\u003c\/td\u003e\n\u003ctd\u003e0–600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e0–60 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e0–60 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e0–300 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-30 to +1000 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEST FUNCTIONS\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity test\u003c\/td\u003e\n\u003ctd\u003e0–50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConduction test\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBell ring (buzzer)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery test\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOWER \u0026amp; ENVIRONMENT\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eBattery powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003e2 × 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking temperature range\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 75% Rh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLOGISTICS\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct weight\u003c\/td\u003e\n\u003ctd\u003e0.165 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross weight\u003c\/td\u003e\n\u003ctd\u003e0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolume\u003c\/td\u003e\n\u003ctd\u003e1.309\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003eNote: Meters capable of measuring DC current, including YT-730934, use a Hall sensor that measures the value of magnetic field strength. The magnetic field on Earth occurs naturally, consequently, the DC intensity meter readings are non-zero. Each time, before measuring the DC intensity, bring the meter close to the wire under test, zero it with the REL button, then clip it onto the wire under test and read the result.\u003c\/p\u003e\n\u003ch2\u003eBasic measurements:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC voltage measurement: A.C. 0-600 V, TRUE RMS (40-1000Hz)\u003c\/li\u003e\n\u003cli\u003eDC voltage measurement: D.C. 0-600 V\u003c\/li\u003e\n\u003cli\u003ealternating current measurement: A.C. 0-600 A, TRUE RMS (40-1000Hz)\u003c\/li\u003e\n\u003cli\u003eDC current measurement: D.C. 0-600 A\u003c\/li\u003e\n\u003cli\u003eresistance measurement: 0-60 MΩ\u003c\/li\u003e\n\u003cli\u003ediode test:IF 1.5 mA,UR 3 V\u003c\/li\u003e\n\u003cli\u003ecircuit continuity test: 0-50 Ω\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAdditional measurements:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eA.C. and D.C. voltage measurement in low impedance mode: 0-600 V\u003c\/li\u003e\n\u003cli\u003ecapacitor measurement: 0-60 mF\u003c\/li\u003e\n\u003cli\u003efrequency measurement: 0-300 kHz\u003c\/li\u003e\n\u003cli\u003etemperature measurement: -30 to 1000 °C\u003c\/li\u003e\n\u003cli\u003enon-contact AC voltage detection: NCV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eMeasurement accuracies:\u003c\/h2\u003e\n\u003cp\u003eExample of accuracy determination for AC current measurement. Calculation for the measurement result: 30 A\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe measurement accuracy of YT-730934 meter for this range is : ±(2.0%+30), resolution 0.01 A\u003c\/li\u003e\n\u003cli\u003ecalculation of measurement error formula: (measurement result x 2%) + 30 x resolution\u003c\/li\u003e\n\u003cli\u003ecalculation: (30 x 2%) + 30 x 0.01 = 0.6 + 0.3 = 0.90 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eActual result including measurement error for 30 A indication = 30 ± 0.90 A.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eResult including measurement error for AC voltage measurement indication: 235 V = 235 ± 2.65 V\u003c\/li\u003e\n\u003cli\u003eresult including measurement error for DC voltage measurement indication: 12 V = 12 ± 0.09 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA table with the resolution and accuracy for the measurement can be found in the user's manual.\u003c\/p\u003e\n\u003ch2\u003eBuilt-in functions:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTRUE RMS - a meter with this function displays the true rms value of AC voltage\/voltage. Unlike averaging meters, devices with true rms show the correct value not only for sinusoidal waveforms, but also for sinusoidal waveforms distorted, such as by higher harmonics, or square or triangular waveforms. A must-have function wherever pulse power supplies, motor inverter drives, HVAC installations, etc. appear in a circuit.\u003c\/li\u003e\n\u003cli\u003eVlowZ - measurement of AC and DC voltage in low impedance mode. The phenomenon colloquially called ghost voltage can make it difficult to diagnose power networks, for example, in industrial buildings. It consists in the appearance of a voltage on an unconnected wire, in which the voltage is induced from the mains-connected wire routed through the same channel. The LowZ function lowers the impedance of the meter's measuring sockets by 10 times compared to the standard measurement mode, then the meter sampling the voltage draws a slightly higher current and thus discharges the accumulated charge in the wire. The result is a voltage measurement devoid of the so-called ghost voltage.\u003c\/li\u003e\n\u003cli\u003eNCV - non-contact AC voltage detection by inductive method. The meter detects the presence of voltage in an insulated wire, it can also indicate the phase wire\u003c\/li\u003e\n\u003cli\u003eAUTO - automatic adjustment of the measurement range. When measuring unknown values with a meter with manual range adjustment using the knob, make measurements sequentially from the largest range up to the range giving the most accurate result - otherwise you risk damaging the device. On the other hand, in the case of a multimeter with the AUTO function, you only need to make one measurement and the meter will automatically find the optimal range. The meter starts by default in AUTO mode\u003c\/li\u003e\n\u003cli\u003eDATA HOLD - retaining the currently measured value on the display\u003c\/li\u003e\n\u003cli\u003ePEAK HOLD - retaining on the display the highest measured value by means of measuring probes\u003c\/li\u003e\n\u003cli\u003eINRUSH current - measurement of inrush current by means of measuring probes. The meter will measure the current within 100 ms of starting the device\u003c\/li\u003e\n\u003cli\u003eREL - relative value function. Allows you to zero the meter's readings. Necessary in DC current measurement mode. Hall sensor measures the value of the ambient electromagnetic field and shows the result on the display. Before measuring the DC current, bring the meter close to the wire under test, zero it, then put the pincers on the wire under test. This will give a result undisturbed by the values of the ambient electromagnetic field indications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAdditional information:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLCD display, maximum displayed result: 6000\u003c\/li\u003e\n\u003cli\u003ebacklighting of the screen and the measuring field of the clamps\u003c\/li\u003e\n\u003cli\u003eaudible signal in the test of circuit continuity for resistance below 50Ω\u003c\/li\u003e\n\u003cli\u003epossibility to enable diode and circuit continuity tests separately\u003c\/li\u003e\n\u003cli\u003eclamps open up to 25 mm and allow measurement of a single wire with a maximum diameter of 25 mm\u003c\/li\u003e\n\u003cli\u003emeasuring probes with a length of 14.5 cm\u003c\/li\u003e\n\u003cli\u003ecable length including probes: 97 cm\u003c\/li\u003e\n\u003cli\u003ecable diameter including insulation: 3.5 mm\u003c\/li\u003e\n\u003cli\u003ethe set comes with a carrying case\u003c\/li\u003e\n\u003cli\u003econstruction with overload protection\u003c\/li\u003e\n\u003cli\u003eautomatic shutdown of the meter after 15 minutes of inactivity\u003c\/li\u003e\n\u003cli\u003epossibility to disable the automatic shutdown mode\u003c\/li\u003e\n\u003cli\u003elow battery indicator\u003c\/li\u003e\n\u003cli\u003epower supply: two 1.5V (AAA) batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAttention!\u003c\/h3\u003e\n\u003cp\u003eCurrent measurement with clamps meters is performed only on a single wire, single cable. Fastening the clamps on a multiconductor cable without isolating the single conductor will show an incorrect result or zero current flow.\u003c\/p\u003e","brand":"YATO","offers":[{"title":"10MA-600A","offer_id":57197507019077,"sku":"000296-10600","price":39.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/7012df17-716e-48cc-ae83-7f9c36de6a68.jpg?v=1771528485"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/collections\/f9f1fa56-82e9-4041-ae06-6d67bcac1e7c_0f5b2c80-0e66-4999-b7f4-ec6f544433cb.jpg?v=1771529719","url":"https:\/\/www.periplusmro.com\/collections\/digital-multimeters.oembed","provider":"PERIPLUS MRO SHOP","version":"1.0","type":"link"}