{"title":"Clamp Meters","description":"\u003cp\u003eExplore clamp meters for safe, non-invasive electrical measurement, including AC, AC\/DC, True RMS and leakage models for current, voltage, resistance and industrial diagnostics.\u003c\/p\u003e","products":[{"product_id":"clamp-multimeter-true-rms-ac-dc-600a-ncv-yato-yt-730934","title":"YATO Clamp Multimeter, True RMS AC\/DC 10 mA–600 A – YT-730934","description":"\u003cp\u003eThe universal clamp meter with automatic range for each measurement allows you to perform basic and advanced measurements of electrical quantities. The meter is equipped with measuring clamps that allow to measure DC as well as AC current in a single wire by means of a built-in HALL sensor. The measurement is carried out without disconnecting the circuit or disconnecting it from the power source, and makes it possible to measure much higher current than conventional electric meters. The leads of the measuring probes have silicone insulation, which is flexible and resistant to high temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/0-60_mF.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/0-60_M-OMEGA.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/0-300_kHz.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/0-600A_AC.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/0-600A_DC.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/0-600V_AC.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/0-600V_DC.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/AAA_2x_a3f76caf-6766-4a28-b891-fa0981af447c.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/AUTO_POWER_OFF_ENG.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/AUTO_RANGE_ENG.png?v=1779199892\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/BUZZER.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/DATA_HOLD.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/DIODE.png?v=1779199892\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/FRONT_LIGHT_ENG.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/LCD_6000.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/LED_BACKLIGHT_ENG.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/NCV.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/PEAK_HOLD.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/TEMP_-30__2B1000_C.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/TEST_INDUCTION.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/TRUE_RMS.png?v=1779199893\" alt=\"\" width=\"81\" height=\"81\"\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGENERAL\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct name\u003c\/td\u003e\n\u003ctd\u003eClamp Multimeter, TRUE RMS AC\/DC 10 mA–600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand \/ Index\u003c\/td\u003e\n\u003ctd\u003eYATO \/ YT-730934\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit of measure\u003c\/td\u003e\n\u003ctd\u003ePCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSIZE \u0026amp; CLAMP\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185 × 65 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax cable diameter (clamp)\u003c\/td\u003e\n\u003ctd\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax clamp gap\u003c\/td\u003e\n\u003ctd\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDISPLAY \u0026amp; FEATURES\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay type\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e6000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED backlight\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront lighting\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTRUE RMS\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNCV (Non-contact AC voltage detection)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak value hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto measurement range\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling frequency\u003c\/td\u003e\n\u003ctd\u003e3 times per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto power off\u003c\/td\u003e\n\u003ctd\u003e15 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow battery indicator\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMEASUREMENT RANGES\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC voltage\u003c\/td\u003e\n\u003ctd\u003e0–600 V a.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e0–600 V d.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current (clamp)\u003c\/td\u003e\n\u003ctd\u003e0–600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC current (clamp)\u003c\/td\u003e\n\u003ctd\u003e0–600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e0–60 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e0–60 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e0–300 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-30 to +1000 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEST FUNCTIONS\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity test\u003c\/td\u003e\n\u003ctd\u003e0–50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConduction test\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBell ring (buzzer)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery test\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOWER \u0026amp; ENVIRONMENT\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eBattery powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003e2 × 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking temperature range\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 75% Rh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLOGISTICS\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct weight\u003c\/td\u003e\n\u003ctd\u003e0.165 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross weight\u003c\/td\u003e\n\u003ctd\u003e0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolume\u003c\/td\u003e\n\u003ctd\u003e1.309\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003eNote: Meters capable of measuring DC current, including YT-730934, use a Hall sensor that measures the value of magnetic field strength. The magnetic field on Earth occurs naturally, consequently, the DC intensity meter readings are non-zero. Each time, before measuring the DC intensity, bring the meter close to the wire under test, zero it with the REL button, then clip it onto the wire under test and read the result.\u003c\/p\u003e\n\u003ch2\u003eBasic measurements:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC voltage measurement: A.C. 0-600 V, TRUE RMS (40-1000Hz)\u003c\/li\u003e\n\u003cli\u003eDC voltage measurement: D.C. 0-600 V\u003c\/li\u003e\n\u003cli\u003ealternating current measurement: A.C. 0-600 A, TRUE RMS (40-1000Hz)\u003c\/li\u003e\n\u003cli\u003eDC current measurement: D.C. 0-600 A\u003c\/li\u003e\n\u003cli\u003eresistance measurement: 0-60 MΩ\u003c\/li\u003e\n\u003cli\u003ediode test:IF 1.5 mA,UR 3 V\u003c\/li\u003e\n\u003cli\u003ecircuit continuity test: 0-50 Ω\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAdditional measurements:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eA.C. and D.C. voltage measurement in low impedance mode: 0-600 V\u003c\/li\u003e\n\u003cli\u003ecapacitor measurement: 0-60 mF\u003c\/li\u003e\n\u003cli\u003efrequency measurement: 0-300 kHz\u003c\/li\u003e\n\u003cli\u003etemperature measurement: -30 to 1000 °C\u003c\/li\u003e\n\u003cli\u003enon-contact AC voltage detection: NCV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eMeasurement accuracies:\u003c\/h2\u003e\n\u003cp\u003eExample of accuracy determination for AC current measurement. Calculation for the measurement result: 30 A\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe measurement accuracy of YT-730934 meter for this range is : ±(2.0%+30), resolution 0.01 A\u003c\/li\u003e\n\u003cli\u003ecalculation of measurement error formula: (measurement result x 2%) + 30 x resolution\u003c\/li\u003e\n\u003cli\u003ecalculation: (30 x 2%) + 30 x 0.01 = 0.6 + 0.3 = 0.90 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eActual result including measurement error for 30 A indication = 30 ± 0.90 A.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eResult including measurement error for AC voltage measurement indication: 235 V = 235 ± 2.65 V\u003c\/li\u003e\n\u003cli\u003eresult including measurement error for DC voltage measurement indication: 12 V = 12 ± 0.09 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA table with the resolution and accuracy for the measurement can be found in the user's manual.\u003c\/p\u003e\n\u003ch2\u003eBuilt-in functions:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTRUE RMS - a meter with this function displays the true rms value of AC voltage\/voltage. Unlike averaging meters, devices with true rms show the correct value not only for sinusoidal waveforms, but also for sinusoidal waveforms distorted, such as by higher harmonics, or square or triangular waveforms. A must-have function wherever pulse power supplies, motor inverter drives, HVAC installations, etc. appear in a circuit.\u003c\/li\u003e\n\u003cli\u003eVlowZ - measurement of AC and DC voltage in low impedance mode. The phenomenon colloquially called ghost voltage can make it difficult to diagnose power networks, for example, in industrial buildings. It consists in the appearance of a voltage on an unconnected wire, in which the voltage is induced from the mains-connected wire routed through the same channel. The LowZ function lowers the impedance of the meter's measuring sockets by 10 times compared to the standard measurement mode, then the meter sampling the voltage draws a slightly higher current and thus discharges the accumulated charge in the wire. The result is a voltage measurement devoid of the so-called ghost voltage.\u003c\/li\u003e\n\u003cli\u003eNCV - non-contact AC voltage detection by inductive method. The meter detects the presence of voltage in an insulated wire, it can also indicate the phase wire\u003c\/li\u003e\n\u003cli\u003eAUTO - automatic adjustment of the measurement range. When measuring unknown values with a meter with manual range adjustment using the knob, make measurements sequentially from the largest range up to the range giving the most accurate result - otherwise you risk damaging the device. On the other hand, in the case of a multimeter with the AUTO function, you only need to make one measurement and the meter will automatically find the optimal range. The meter starts by default in AUTO mode\u003c\/li\u003e\n\u003cli\u003eDATA HOLD - retaining the currently measured value on the display\u003c\/li\u003e\n\u003cli\u003ePEAK HOLD - retaining on the display the highest measured value by means of measuring probes\u003c\/li\u003e\n\u003cli\u003eINRUSH current - measurement of inrush current by means of measuring probes. The meter will measure the current within 100 ms of starting the device\u003c\/li\u003e\n\u003cli\u003eREL - relative value function. Allows you to zero the meter's readings. Necessary in DC current measurement mode. Hall sensor measures the value of the ambient electromagnetic field and shows the result on the display. Before measuring the DC current, bring the meter close to the wire under test, zero it, then put the pincers on the wire under test. This will give a result undisturbed by the values of the ambient electromagnetic field indications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAdditional information:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLCD display, maximum displayed result: 6000\u003c\/li\u003e\n\u003cli\u003ebacklighting of the screen and the measuring field of the clamps\u003c\/li\u003e\n\u003cli\u003eaudible signal in the test of circuit continuity for resistance below 50Ω\u003c\/li\u003e\n\u003cli\u003epossibility to enable diode and circuit continuity tests separately\u003c\/li\u003e\n\u003cli\u003eclamps open up to 25 mm and allow measurement of a single wire with a maximum diameter of 25 mm\u003c\/li\u003e\n\u003cli\u003emeasuring probes with a length of 14.5 cm\u003c\/li\u003e\n\u003cli\u003ecable length including probes: 97 cm\u003c\/li\u003e\n\u003cli\u003ecable diameter including insulation: 3.5 mm\u003c\/li\u003e\n\u003cli\u003ethe set comes with a carrying case\u003c\/li\u003e\n\u003cli\u003econstruction with overload protection\u003c\/li\u003e\n\u003cli\u003eautomatic shutdown of the meter after 15 minutes of inactivity\u003c\/li\u003e\n\u003cli\u003epossibility to disable the automatic shutdown mode\u003c\/li\u003e\n\u003cli\u003elow battery indicator\u003c\/li\u003e\n\u003cli\u003epower supply: two 1.5V (AAA) batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAttention!\u003c\/h3\u003e\n\u003cp\u003eCurrent measurement with clamps meters is performed only on a single wire, single cable. Fastening the clamps on a multiconductor cable without isolating the single conductor will show an incorrect result or zero current flow.\u003c\/p\u003e","brand":"YATO","offers":[{"title":"10MA-600A","offer_id":57197507019077,"sku":"000296-10600","price":39.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/7012df17-716e-48cc-ae83-7f9c36de6a68.jpg?v=1771528485"},{"product_id":"uni-t-ut210e-100a-true-rms-mini-ac-dc-clamp-meter","title":"UNI-T True RMS Mini AC\/DC Clamp Meter, 100 A, 2000 Counts, NCV, 17 mm Jaw – UT210E","description":"\u003cp\u003eThe UNI-T UT210E is a compact True RMS clamp meter for measuring AC and DC current up to 100A. It also measures AC\/DC voltage, resistance and capacitance, while VFC and NCV functions support electrical maintenance and variable-frequency drive diagnostics.\u003c\/p\u003e\n\u003cdiv style=\"font-family: Helvetica, Arial, sans-serif; color: #000000; font-size: 12pt; line-height: 1.5;\"\u003e\n\u003ch2 style=\"font-size: 14pt;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures AC and DC current across 2A, 20A and 100A ranges, with a minimum resolution of 1mA.\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement provides reliable AC current and voltage readings on both sinusoidal and non-sinusoidal signals.\u003c\/li\u003e\n\u003cli\u003eMeasures AC\/DC voltage up to 600V, resistance up to 20MΩ and capacitance up to 20mF.\u003c\/li\u003e\n\u003cli\u003eVFC low-pass filter supports measurements on variable-frequency drives and motor-control equipment.\u003c\/li\u003e\n\u003cli\u003eIntegrated NCV detection, ZERO mode, Data Hold and a backlit display support efficient electrical troubleshooting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt;\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 8px; text-align: left; background-color: #f5f5f5;\" colspan=\"2\"\u003eCurrent Measurement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px; width: 40%;\"\u003eAC Current Ranges\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e2A \/ 20A \/ 100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eAC Current Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e±(2.5% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eDC Current Ranges\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e2A \/ 20A \/ 100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eDC Current Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e±(2% + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eMinimum Current Resolution\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e1mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eTrue RMS for AC current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 8px; text-align: left; background-color: #f5f5f5;\" colspan=\"2\"\u003eVoltage Measurement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eAC Voltage Ranges\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e2V \/ 20V \/ 200V \/ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eAC Voltage Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e±(1% + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eDC Voltage Ranges\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e200mV \/ 2V \/ 20V \/ 200V \/ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eDC Voltage Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e±(0.7% + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eAC Voltage Measurement Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eTrue RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eAt least 10MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 8px; text-align: left; background-color: #f5f5f5;\" colspan=\"2\"\u003eResistance and Capacitance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eResistance Ranges\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e200Ω \/ 2kΩ \/ 20kΩ \/ 200kΩ \/ 2MΩ \/ 20MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eResistance Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e±(1% + 2 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eCapacitance Ranges\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e2nF \/ 20nF \/ 200nF \/ 2µF \/ 20µF \/ 200µF \/ 2mF \/ 20mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eCapacitance Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e±(4% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 8px; text-align: left; background-color: #f5f5f5;\" colspan=\"2\"\u003eDisplay and Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eMaximum Display\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e2000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eJaw Opening\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eApproximately 17mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eRanging\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eAutomatic for voltage, resistance and capacitance; selectable current ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eVFC Mode\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eLow-pass filtered AC voltage and current measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eNCV Detection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eNon-contact AC electric-field detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eAdditional Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eZERO mode, Data Hold, continuity buzzer and diode test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eDiode Test Voltage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eApproximately 3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eLCD Backlight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eAutomatic Power-Off\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eAfter approximately 15 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eLow-Battery Indication\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 8px; text-align: left; background-color: #f5f5f5;\" colspan=\"2\"\u003eGeneral\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eSafety Category\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eCAT II 600V \/ CAT III 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e2 × 1.5V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eLCD Size\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e39.3 × 26.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eProduct Dimensions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e175 × 60 × 33.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eApproximately 170g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eProduct Colour\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eRed and grey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eCE, UKCA and cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 14pt;\"\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC and DC current measurement in control panels, machinery and electrical installations.\u003c\/li\u003e\n\u003cli\u003eTesting variable-frequency drives, motor controls and inverter-powered equipment.\u003c\/li\u003e\n\u003cli\u003eMaintenance of automotive electrical systems, battery-powered equipment and DC circuits.\u003c\/li\u003e\n\u003cli\u003eElectrical installation, appliance servicing and fault finding in confined spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt;\"\u003eIncluded Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUNI-T UT210E True RMS mini AC\/DC clamp meter\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003e2 × 1.5V AAA batteries\u003c\/li\u003e\n\u003cli\u003eCarrying bag\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"UT210E","offer_id":58751318065477,"sku":"003110","price":54.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/0dbc618e-6d7d-40ef-ab26-145b3343fe47.jpg?v=1785742922"},{"product_id":"uni-t-ut210b-200a-true-rms-mini-ac-clamp-meter","title":"UNI-T True RMS Mini AC Clamp Meter, 200 A, 2000 Counts, 16 mm Jaw – UT210B","description":"\u003cp\u003eThe UNI-T UT210B is a compact True RMS clamp meter for non-contact AC current measurement up to 200A. Its narrow jaw, NCV detection and MAX\/MIN functions make it suitable for electrical maintenance and measurements in confined spaces.\u003c\/p\u003e\n\u003cdiv style=\"font-family: Helvetica, Arial, sans-serif; color: #000000; font-size: 12pt; line-height: 1.5;\"\u003e\n\u003ch2 style=\"font-size: 14pt;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS measurement provides reliable AC current readings on both sinusoidal and non-sinusoidal signals.\u003c\/li\u003e\n\u003cli\u003eMeasures AC current across 2A, 20A and 200A ranges without disconnecting the conductor.\u003c\/li\u003e\n\u003cli\u003eCompact body and approximately 16mm jaw opening provide easier access to conductors in confined panels and crowded wiring.\u003c\/li\u003e\n\u003cli\u003eIntegrated NCV function enables non-contact detection of nearby AC electric fields.\u003c\/li\u003e\n\u003cli\u003eMAX\/MIN, relative and Data Hold functions are supported by a 2000-count backlit display and automatic power-off.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt;\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 8px; text-align: left; background-color: #f5f5f5;\" colspan=\"2\"\u003eAC Current Measurement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px; width: 40%;\"\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eTrue RMS AC current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eCurrent Ranges\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e2A \/ 20A \/ 200A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eMaximum Current\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e200A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e1mA \/ 10mA \/ 100mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eBasic Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e±(2.5% + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eSampling Rate\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eApproximately 2–3 readings per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 8px; text-align: left; background-color: #f5f5f5;\" colspan=\"2\"\u003eDisplay and Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eMaximum Display\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e2000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eJaw Opening\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eApproximately 16mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eNCV Detection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eNon-contact AC electric-field detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eMeasurement Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eMAX\/MIN, relative mode and Data Hold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eLCD Backlight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eAutomatic Power-Off\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eAfter approximately 15 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eLow-Battery Indication\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eInput Protection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eFull-range overload protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 8px; text-align: left; background-color: #f5f5f5;\" colspan=\"2\"\u003eGeneral\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eSafety Category\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eCAT II 600V \/ CAT III 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e2 × 1.5V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eLCD Size\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e39.3 × 26.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eProduct Dimensions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e158 × 60 × 33.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eApproximately 150g, including batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eProduct Colour\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eRed and grey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eCE, UKCA and cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 14pt;\"\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC current measurement in compact distribution boards and control panels.\u003c\/li\u003e\n\u003cli\u003eMaintenance of household appliances and small electrical equipment.\u003c\/li\u003e\n\u003cli\u003eInspection of motor controls, power supplies and branch circuits.\u003c\/li\u003e\n\u003cli\u003eElectrical installation, troubleshooting and routine maintenance in confined spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt;\"\u003eIncluded Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUNI-T UT210B True RMS mini AC clamp meter\u003c\/li\u003e\n\u003cli\u003e2 × 1.5V AAA batteries\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunction Note:\u003c\/strong\u003e The UT210B measures AC current only. It does not measure DC current, voltage or resistance.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"UT210B","offer_id":58751318131013,"sku":"003109","price":27.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/9f7a272a-ae21-4998-ac61-bb7784ac6c72.jpg?v=1785742923"},{"product_id":"uni-t-ut210a-200a-mini-ac-clamp-meter","title":"UNI-T Mini Digital AC Clamp Meter, 200 A, 2000 Counts, 16 mm Jaw – UT210A","description":"\u003cp\u003eThe UNI-T UT210A is a compact clamp meter designed exclusively for non-contact AC current measurement up to 200A. Its 1mA minimum resolution and narrow jaw make it suitable for checking small current signals and conductors in confined spaces.\u003c\/p\u003e\n\u003cdiv style=\"font-family: Helvetica, Arial, sans-serif; color: #000000; font-size: 12pt; line-height: 1.5;\"\u003e\n\u003ch2 style=\"font-size: 14pt;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures AC current across selectable 2A, 20A and 200A ranges without disconnecting the conductor.\u003c\/li\u003e\n\u003cli\u003eMinimum 1mA resolution supports measurement of relatively small AC current signals.\u003c\/li\u003e\n\u003cli\u003eCompact body and approximately 17mm jaw opening provide easier access in confined panels and crowded wiring installations.\u003c\/li\u003e\n\u003cli\u003eData Hold and Maximum Hold functions allow readings to be retained when the display is difficult to view during measurement.\u003c\/li\u003e\n\u003cli\u003e2000-count backlit display, low-battery indication and automatic power-off support convenient everyday operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt;\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 8px; text-align: left; background-color: #f5f5f5;\" colspan=\"2\"\u003eAC Current Measurement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px; width: 40%;\"\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eAverage-responding AC current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eCurrent Ranges\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e2A \/ 20A \/ 200A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eMaximum Current\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e200A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eMinimum Resolution\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e1mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eBasic Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e±(2.5% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 8px; text-align: left; background-color: #f5f5f5;\" colspan=\"2\"\u003eDisplay and Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eMaximum Display\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e2000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eJaw Opening\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eApproximately 17mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eData Hold\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eMaximum Hold\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eLCD Backlight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eAutomatic Power-Off\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eAfter approximately 15 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eLow-Battery Indication\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 8px; text-align: left; background-color: #f5f5f5;\" colspan=\"2\"\u003eGeneral\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e2 × 1.5V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eLCD Size\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e39.3 × 26.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eProduct Dimensions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003e155 × 60 × 33.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eApproximately 160g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eProduct Colour\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eRed and grey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 8px;\"\u003eCE, UKCA and cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 14pt;\"\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC current checks in compact distribution boards and crowded wiring installations.\u003c\/li\u003e\n\u003cli\u003eMaintenance of household appliances and small electrical equipment.\u003c\/li\u003e\n\u003cli\u003eInspection of control panels, power supplies and branch circuits.\u003c\/li\u003e\n\u003cli\u003eElectrical troubleshooting, installation work and routine maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt;\"\u003eIncluded Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUNI-T UT210A mini AC clamp meter\u003c\/li\u003e\n\u003cli\u003eWrist strap\u003c\/li\u003e\n\u003cli\u003e2 × 1.5V AAA batteries\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunction Note:\u003c\/strong\u003e The UT210A measures AC current only. It does not measure voltage, resistance or DC current and is not a True RMS meter.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"UT210A","offer_id":58751318196549,"sku":"003108","price":21.53,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/339571a8-f77a-427a-83cb-7652c63ced82.jpg?v=1785742926"},{"product_id":"uni-t-ut256b-200a-true-rms-ac-dc-open-jaw-clamp-meter","title":"UNI-T True RMS AC\/DC Fork Meter, 200 A, 6000 Counts, NCV \u0026 Capacitance – UT256B","description":"The UNI-T UT256B is a True RMS open-jaw clamp meter for measuring AC and DC current up to 200A without disconnecting the conductor. Its fork-style 14.7mm opening provides quick access in crowded panels, while additional voltage, resistance and capacitance functions support electrical troubleshooting.\u003cdiv style=\"font-family: Helvetica, Arial, sans-serif; color: #000000; font-size: 12pt; line-height: 1.5;\"\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 0 0 10px 0;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eMeasures AC and DC current up to 200A with 0.1A resolution\u003c\/li\u003e\n\u003cli\u003eOpen-jaw fork design accepts conductors up to approximately 14.7mm in diameter\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement for improved accuracy on non-sinusoidal signals\u003c\/li\u003e\n\u003cli\u003eMeasures AC\/DC voltage, resistance and capacitance\u003c\/li\u003e\n\u003cli\u003eNCV detection, zero, relative and data-hold functions for electrical troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 12pt;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 40%; border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUNI-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUT256B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMeter Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTrue RMS AC\/DC open-jaw clamp meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Resolution\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e0.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(2.5% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Frequency Response\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e50Hz to 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Current Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Current Resolution\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e0.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Current Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(2.5% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(1.2% + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Voltage Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(0.8% + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eResistance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 60MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 60mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDisplay Count\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e6000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMeasurement Response\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTrue RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMaximum Conductor Diameter\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eApproximately 14.7mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eRanging\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eVoltage Detection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNCV non-contact AC voltage detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Test Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDiode test and audible continuity test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eZero mode, relative mode, data hold, LCD backlight and automatic power-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e≥10MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eSafety Category\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCAT II 1000V \/ CAT III 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCE, RoHS and cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e2 × 1.5V AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDisplay Size\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e36.5 × 24mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e210 × 53 × 35mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eApproximately 164g including batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eCurrent measurement in crowded electrical panels\u003c\/li\u003e\n\u003cli\u003eAutomotive and battery-powered DC system testing\u003c\/li\u003e\n\u003cli\u003eElectrical installation inspection and troubleshooting\u003c\/li\u003e\n\u003cli\u003eControl-panel and industrial equipment maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eIncluded Components\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eUNI-T UT256B True RMS AC\/DC open-jaw clamp meter\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003e2 × 1.5V AA batteries\u003c\/li\u003e\n\u003cli\u003eCarrying bag and user documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"UT256B","offer_id":58761603580229,"sku":"003122","price":72.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/ae175507-02c1-447e-b8cd-854960c4f919.jpg?v=1785826666"},{"product_id":"uni-t-ut220-2000a-digital-ac-clamp-meter","title":"UNI-T Digital AC Clamp Meter, 2000 A, 2000 Counts, Max\/Min \u0026 Data Hold – UT220","description":"The UNI-T UT220 is a large-jaw digital clamp meter designed to measure alternating current up to 2000A without disconnecting the conductor. It also measures AC\/DC voltage and resistance, making it suitable for industrial electrical installation, inspection and maintenance work.\u003cdiv style=\"font-family: Helvetica, Arial, sans-serif; color: #000000; font-size: 12pt; line-height: 1.5;\"\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 0 0 10px 0;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eMeasures alternating current up to 2000A without disconnecting the conductor\u003c\/li\u003e\n\u003cli\u003eLarge 63mm jaw opening for industrial cables and conductors\u003c\/li\u003e\n\u003cli\u003eMeasures AC voltage up to 750V, DC voltage up to 1000V and resistance up to 20MΩ\u003c\/li\u003e\n\u003cli\u003eAutomatic ranging with data hold and maximum\/minimum value functions\u003c\/li\u003e\n\u003cli\u003eOverload protection across all ranges for industrial electrical measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 12pt;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 40%; border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUNI-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUT220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMeter Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDigital AC clamp meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 2000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(2.5% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Current Measurement\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(1.2% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Voltage Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(0.8% + 1 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eResistance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 20MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eResistance Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(1% + 2 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDisplay Count\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e2000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eJaw Opening\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e63mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eRanging\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Test Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDiode test and audible continuity test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eData hold, maximum\/minimum values and low-battery indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTrue RMS\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e≥10MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eSafety Category\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCAT III 1000V \/ CAT IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCE, UKCA and cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e1 × 9V battery (6F22)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDisplay Size\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e43 × 30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e298 × 107 × 47mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eApproximately 389g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eIndustrial power distribution system inspection\u003c\/li\u003e\n\u003cli\u003eLarge electrical cable and conductor current measurement\u003c\/li\u003e\n\u003cli\u003eElectrical panel, switchgear and distribution-board maintenance\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial electrical troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eIncluded Components\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eUNI-T UT220 digital AC clamp meter\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eCarrying bag\u003c\/li\u003e\n\u003cli\u003eUser documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"UT220","offer_id":58761604137285,"sku":"003114","price":53.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/aeaf4a79-f026-4846-be78-4ead6338bdf5.jpg?v=1785826676"},{"product_id":"uni-t-ut222-2500a-true-rms-ac-dc-clamp-meter","title":"UNI-T True RMS AC\/DC Clamp Meter, 2500 A, 6000 Counts, Data Logging \u0026 Temperature – UT222","description":"The UNI-T UT222 is a True RMS AC\/DC clamp meter designed for measuring currents up to 2500A through its large 63mm jaw. It combines high-current measurement with voltage, resistance, capacitance, frequency and temperature functions for industrial electrical testing and maintenance.\u003cdiv style=\"font-family: Helvetica, Arial, sans-serif; color: #000000; font-size: 12pt; line-height: 1.5;\"\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 0 0 10px 0;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eMeasures AC and DC current up to 2500A through a 63mm jaw\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement for improved accuracy on non-sinusoidal signals\u003c\/li\u003e\n\u003cli\u003eMeasures AC\/DC voltage, resistance, capacitance, frequency and temperature\u003c\/li\u003e\n\u003cli\u003eInrush-current and low-pass filter functions for industrial equipment testing\u003c\/li\u003e\n\u003cli\u003eStores up to 1000 readings for measurement review and documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 12pt;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 40%; border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUNI-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUT222\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMeter Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTrue RMS AC\/DC clamp meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 2500A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Current Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 2500A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC\/DC Current Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(1.5% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(1% + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Voltage Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(0.5% + 2 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eResistance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 60MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 60mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eFrequency Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 60MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e-40°C to 1000°C \/ -40°F to 1832°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDisplay Count\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e6000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eJaw Opening\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e63mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMeasurement Response\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTrue RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eSpecial Measurement Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC+DC, inrush current, low-pass filter, duty cycle and relative mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Test Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDiode test and audible continuity test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eData hold, maximum\/minimum values, analogue bar graph and I-OUT function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eData Storage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e1000 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e≥10MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eSafety Category\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCAT III 1000V \/ CAT IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCE, UKCA and cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e1 × 9V battery (6F22)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDisplay Size\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e43 × 30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e298 × 107 × 47mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eApproximately 726g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eIndustrial power distribution and high-current system inspection\u003c\/li\u003e\n\u003cli\u003eMotor, generator and large electrical equipment maintenance\u003c\/li\u003e\n\u003cli\u003eVariable-frequency drive and inrush-current testing\u003c\/li\u003e\n\u003cli\u003eElectrical panel, switchgear and industrial cable troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eIncluded Components\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eUNI-T UT222 True RMS AC\/DC clamp meter\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eCurrent output cable\u003c\/li\u003e\n\u003cli\u003eTemperature thermocouple\u003c\/li\u003e\n\u003cli\u003eTool case and user documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"UT222","offer_id":58761604301125,"sku":"003115","price":210.74,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/3310f4e9-b49b-4409-a7ed-b2cb031262fd.jpg?v=1785826678"},{"product_id":"uni-t-ut213a-400a-digital-ac-clamp-meter","title":"UNI-T Digital AC Clamp Meter, 400 A, 4000 Counts, Capacitance \u0026 NCV – UT213A","description":"\u003cp\u003eThe UNI-T UT213A is an automatic-ranging digital clamp meter for measuring alternating current up to 400A through a 30mm jaw. It also measures AC\/DC voltage, resistance, capacitance and frequency, with NCV detection for everyday electrical inspection and maintenance.\u003c\/p\u003e\n\u003cdiv style=\"font-family: Helvetica, Arial, sans-serif; color: #000000; font-size: 12pt; line-height: 1.5;\"\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 0 0 10px 0;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eMeasures alternating current up to 400A through a 30mm jaw\u003c\/li\u003e\n\u003cli\u003eMeasures AC\/DC voltage, resistance, capacitance and frequency\u003c\/li\u003e\n\u003cli\u003eNon-contact voltage detection for identifying energised conductors\u003c\/li\u003e\n\u003cli\u003eAutomatic ranging with data hold and relative measurement modes\u003c\/li\u003e\n\u003cli\u003eIntegrated LCD backlight and work light for low-light environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 12pt;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 40%; border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUNI-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUT213A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMeter Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDigital AC clamp meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e4A \/ 40A \/ 400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(1.8% + 9 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Current Measurement\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e4V \/ 40V \/ 400V \/ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(1.2% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e400mV \/ 4V \/ 40V \/ 400V \/ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Voltage Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(0.8% + 1 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eResistance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e400Ω to 40MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e50nF to 100μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eFrequency Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e10Hz to 1MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDisplay Count\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e4000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMeasurement Response\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAverage responding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eJaw Opening\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eRanging\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eVoltage Detection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNCV non-contact voltage detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Test Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDiode test and audible continuity test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eData hold, relative mode, LCD backlight, work light and automatic power-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e≥10MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eSafety Category\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCAT III 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCE, UKCA and cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e3 × 1.5V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e220 × 75 × 40mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eApproximately 280g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eElectrical installation inspection and troubleshooting\u003c\/li\u003e\n\u003cli\u003eDistribution-board and electrical panel maintenance\u003c\/li\u003e\n\u003cli\u003eHVAC\/R electrical system servicing\u003c\/li\u003e\n\u003cli\u003eCommercial and light-industrial equipment maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eIncluded Components\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eUNI-T UT213A digital AC clamp meter\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003e3 × 1.5V AAA batteries\u003c\/li\u003e\n\u003cli\u003eCarrying bag and user documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"UT213A","offer_id":58761604661573,"sku":"003116","price":39.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/7b97db70-a747-4ca0-9d39-78dd504c7371.jpg?v=1785826687"},{"product_id":"uni-t-ut213b-400a-true-rms-ac-clamp-meter","title":"UNI-T True RMS AC Clamp Meter, 400 A, 4000 Counts, Temperature \u0026 NCV – UT213B","description":"The UNI-T UT213B is a True RMS digital clamp meter for measuring alternating current up to 400A through a 30mm jaw. It also provides voltage, resistance, capacitance, frequency and temperature measurement for electrical, HVAC\/R and industrial maintenance work.\u003cdiv style=\"font-family: Helvetica, Arial, sans-serif; color: #000000; font-size: 12pt; line-height: 1.5;\"\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 0 0 10px 0;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eMeasures alternating current up to 400A through a 30mm jaw\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement for improved accuracy on non-sinusoidal signals\u003c\/li\u003e\n\u003cli\u003eMeasures AC\/DC voltage, resistance, capacitance, frequency and temperature\u003c\/li\u003e\n\u003cli\u003eNon-contact voltage detection for identifying energised conductors\u003c\/li\u003e\n\u003cli\u003eMaximum\/minimum, relative and data-hold functions for measurement analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 12pt;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 40%; border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUNI-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUT213B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMeter Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTrue RMS digital AC clamp meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(1.8% + 9 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Current Measurement\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(1.2% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Voltage Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(0.8% + 1 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eResistance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 40MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 40mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eFrequency Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e10Hz to 1MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e-40°C to 1000°C \/ -40°F to 1832°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDisplay Count\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e4000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMeasurement Response\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTrue RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eJaw Opening\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eRanging\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eVoltage Detection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNCV non-contact voltage detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Test Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDiode test and audible continuity test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMaximum\/minimum values, relative mode, data hold, LCD backlight, work light and automatic power-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e≥10MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eSafety Category\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCAT III 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCE, UKCA and cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e3 × 1.5V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e220 × 75 × 40mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eApproximately 280g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eElectrical installation inspection and troubleshooting\u003c\/li\u003e\n\u003cli\u003eHVAC\/R electrical and temperature measurements\u003c\/li\u003e\n\u003cli\u003eMotor, distribution-board and electrical panel maintenance\u003c\/li\u003e\n\u003cli\u003eCommercial and light-industrial equipment servicing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eIncluded Components\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eUNI-T UT213B True RMS AC clamp meter\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003ePoint-contact temperature probe\u003c\/li\u003e\n\u003cli\u003e3 × 1.5V AAA batteries\u003c\/li\u003e\n\u003cli\u003eCarrying bag and user documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"UT213B","offer_id":58761604759877,"sku":"003117","price":46.07,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/f283bd67-c651-40fe-a77b-f9810e363b77.jpg?v=1785826689"},{"product_id":"uni-t-ut213c-400a-true-rms-ac-dc-clamp-meter","title":"UNI-T True RMS AC\/DC Clamp Meter, 400 A, 4000 Counts, Temperature \u0026 NCV – UT213C","description":"\u003cp\u003eThe UNI-T UT213C is a True RMS clamp meter for measuring alternating and direct current up to 400A through a 30mm jaw. It also measures voltage, resistance, capacitance, frequency and temperature for comprehensive electrical and HVAC\/R maintenance work.\u003c\/p\u003e\n\u003cdiv style=\"font-family: Helvetica, Arial, sans-serif; color: #000000; font-size: 12pt; line-height: 1.5;\"\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 0 0 10px 0;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eMeasures AC and DC current up to 400A through a 30mm jaw\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement for improved accuracy on non-sinusoidal signals\u003c\/li\u003e\n\u003cli\u003eMeasures AC\/DC voltage, resistance, capacitance, frequency and temperature\u003c\/li\u003e\n\u003cli\u003eNon-contact voltage detection for identifying energised conductors\u003c\/li\u003e\n\u003cli\u003eMaximum\/minimum, relative and data-hold functions for measurement analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 12pt;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 40%; border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUNI-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUT213C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMeter Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTrue RMS digital AC\/DC clamp meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(2.5% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Current Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Current Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(2% + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(1.2% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Voltage Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(0.8% + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eResistance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 40MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 40mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eFrequency Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e10Hz to 1MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e-40°C to 1000°C \/ -40°F to 1832°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDisplay Count\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e4000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMeasurement Response\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTrue RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eJaw Opening\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eRanging\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eVoltage Detection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNCV non-contact voltage detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Test Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDiode test and audible continuity test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMaximum\/minimum values, relative mode, data hold, LCD backlight, work light and automatic power-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e≥10MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eSafety Category\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCAT III 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCE, UKCA and cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e3 × 1.5V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e220 × 75 × 40mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eApproximately 232g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eElectrical installation inspection and troubleshooting\u003c\/li\u003e\n\u003cli\u003eHVAC\/R electrical and temperature measurements\u003c\/li\u003e\n\u003cli\u003eDC power, battery and automotive electrical system testing\u003c\/li\u003e\n\u003cli\u003eMotor, control-panel and industrial equipment maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eIncluded Components\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eUNI-T UT213C True RMS AC\/DC clamp meter\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003ePoint-contact temperature probe\u003c\/li\u003e\n\u003cli\u003e3 × 1.5V AAA batteries\u003c\/li\u003e\n\u003cli\u003eCarrying bag and user documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"UT213C","offer_id":58761605218629,"sku":"003118","price":62.46,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/749ef5bf-3617-4902-a0fb-3b1b56da7704.jpg?v=1785826697"},{"product_id":"uni-t-ut216a-600a-true-rms-ac-clamp-meter","title":"UNI-T True RMS AC Clamp Meter, 600 A, 6000 Counts, NCV \u0026 Flashlight – UT216A","description":"The UNI-T UT216A is a True RMS digital clamp meter for measuring alternating current up to 600A through a 30mm jaw. It also measures AC\/DC voltage, resistance and capacitance, with NCV detection and automatic ranging for electrical installation and maintenance work.\u003cdiv style=\"font-family: Helvetica, Arial, sans-serif; color: #000000; font-size: 12pt; line-height: 1.5;\"\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 0 0 10px 0;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eMeasures alternating current up to 600A through a 30mm jaw\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement for improved accuracy on non-sinusoidal signals\u003c\/li\u003e\n\u003cli\u003eMeasures AC voltage up to 750V and DC voltage up to 1000V\u003c\/li\u003e\n\u003cli\u003eMeasures resistance up to 60MΩ and capacitance up to 60mF\u003c\/li\u003e\n\u003cli\u003eNCV detection, maximum\/minimum, relative and data-hold functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 12pt;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 40%; border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUNI-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUT216A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMeter Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTrue RMS digital AC clamp meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e6A \/ 60A \/ 600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e6A: ±(2.5% + 30 digits); 60A\/600A: ±(2.5% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Frequency Response\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e50Hz to 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Current Measurement\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Frequency Response\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e40Hz to 400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eResistance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 60MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 60mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDisplay Count\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e6000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eSampling Rate\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eApproximately 3 readings per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMeasurement Response\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTrue RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eJaw Opening\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eRanging\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eVoltage Detection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNCV non-contact AC voltage detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Test Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDiode test and audible continuity test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMaximum\/minimum values, relative mode, data hold, LCD backlight, work light and automatic power-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e≥10MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCE, UKCA and cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e3 × 1.5V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDisplay Size\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e38 × 24mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e220 × 75 × 40mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eApproximately 280g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eElectrical installation inspection and troubleshooting\u003c\/li\u003e\n\u003cli\u003eDistribution-board and control-panel maintenance\u003c\/li\u003e\n\u003cli\u003eMotor and industrial electrical equipment testing\u003c\/li\u003e\n\u003cli\u003eCommercial building and facility electrical maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eIncluded Components\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eUNI-T UT216A True RMS AC clamp meter\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003e3 × 1.5V AAA batteries\u003c\/li\u003e\n\u003cli\u003eCarrying bag and user documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"UT216A","offer_id":58761605349701,"sku":"003119","price":53.97,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/0e422fff-5732-44c8-a436-fe1a3eeb6ebe.jpg?v=1785826699"},{"product_id":"uni-t-ut216b-600a-true-rms-ac-clamp-meter","title":"UNI-T True RMS AC Clamp Meter, 600 A, 6000 Counts, VFC \u0026 NCV – UT216B","description":"The UNI-T UT216B is a True RMS digital clamp meter for measuring alternating current up to 600A with a 40–400Hz frequency response. Its VFC low-pass filter and frequency measurement functions make it suitable for variable-frequency drives, power systems and industrial electrical maintenance.\u003cdiv style=\"font-family: Helvetica, Arial, sans-serif; color: #000000; font-size: 12pt; line-height: 1.5;\"\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 0 0 10px 0;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eMeasures alternating current up to 600A with a 40–400Hz frequency response\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement for non-sinusoidal and variable-frequency signals\u003c\/li\u003e\n\u003cli\u003eVFC low-pass filter helps reduce high-frequency interference during drive measurements\u003c\/li\u003e\n\u003cli\u003eMeasures AC\/DC voltage, resistance, capacitance and frequency\u003c\/li\u003e\n\u003cli\u003eNCV detection, maximum\/minimum, relative and data-hold functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 12pt;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 40%; border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUNI-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUT216B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMeter Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTrue RMS digital AC clamp meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e6A \/ 60A \/ 600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to ±(2.5% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Frequency Response\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e40Hz to 400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Current Measurement\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Frequency Response\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e40Hz to 400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eResistance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 60MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 60mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eFrequency Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e10Hz to 1MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDisplay Count\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e6000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eSampling Rate\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eApproximately 3 readings per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMeasurement Response\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTrue RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eJaw Opening\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eRanging\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eLow-Pass Filter\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eVFC mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eVoltage Detection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNCV non-contact AC voltage detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Test Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDiode test and audible continuity test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMaximum\/minimum values, relative mode, data hold, LCD backlight, work light and automatic power-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e≥10MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCE, UKCA and cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e3 × 1.5V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDisplay Size\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e38 × 24mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e220 × 75 × 40mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eApproximately 232g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eVariable-frequency drive and motor-system testing\u003c\/li\u003e\n\u003cli\u003eServer room, data centre and power-supply maintenance\u003c\/li\u003e\n\u003cli\u003eElectrical distribution and control-panel inspection\u003c\/li\u003e\n\u003cli\u003eIndustrial electrical equipment troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eIncluded Components\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eUNI-T UT216B True RMS AC clamp meter\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003e3 × 1.5V AAA batteries\u003c\/li\u003e\n\u003cli\u003eCarrying bag and user documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"UT216B","offer_id":58761605808453,"sku":"003120","price":68.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/c8adc508-a1b9-4f98-a611-acc2aac4390d.jpg?v=1785826707"},{"product_id":"uni-t-ut216c-600a-true-rms-ac-dc-clamp-meter","title":"UNI-T True RMS AC\/DC Clamp Meter, 600 A, 6000 Counts, Inrush \u0026 Temperature – UT216C","description":"\u003cp\u003eThe UNI-T UT216C is a True RMS clamp meter for measuring alternating and direct current up to 600A through a 30mm jaw. It provides VFC filtering, inrush-current capture and temperature measurement for motor drives, power systems and industrial electrical maintenance.\u003c\/p\u003e\n\u003cdiv style=\"font-family: Helvetica, Arial, sans-serif; color: #000000; font-size: 12pt; line-height: 1.5;\"\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 0 0 10px 0;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eMeasures AC and DC current up to 600A through a 30mm jaw\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement with a 40–400Hz AC current frequency response\u003c\/li\u003e\n\u003cli\u003eVFC low-pass filter and inrush-current capture for motor-drive testing\u003c\/li\u003e\n\u003cli\u003eMeasures AC\/DC voltage, resistance, capacitance, frequency and temperature\u003c\/li\u003e\n\u003cli\u003eNCV detection, zero, maximum\/minimum, relative and data-hold functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 12pt;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 40%; border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #000000; padding: 7px; text-align: left; background-color: #f5f5f5;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUNI-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUT216C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMeter Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTrue RMS digital AC\/DC clamp meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(2.5% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Current Frequency Response\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e40Hz to 400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Current Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Current Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e±(2.5% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAC Voltage Frequency Response\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e40Hz to 400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eResistance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 60MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eUp to 60mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eFrequency Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e10Hz to 1MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e-40°C to 1000°C \/ -40°F to 1832°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDisplay Count\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e6000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAnalogue Bar Graph\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e61 segments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eSampling Rate\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eApproximately 3 readings per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eMeasurement Response\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eTrue RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eJaw Opening\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eRanging\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eLow-Pass Filter\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eVFC mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eInrush Current\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eVoltage Detection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNCV non-contact AC voltage detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Test Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDiode test and audible continuity test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eAdditional Functions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eZero mode, maximum\/minimum values, relative mode, data hold, LCD backlight, work light and automatic power-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e≥10MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eCE, UKCA and cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e3 × 1.5V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDisplay Size\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e38 × 24mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003e220 × 75 × 40mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000; padding: 7px;\"\u003eApproximately 232g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eVariable-frequency drive and motor-system testing\u003c\/li\u003e\n\u003cli\u003eAC and DC power-system troubleshooting\u003c\/li\u003e\n\u003cli\u003eHVAC\/R electrical and temperature measurements\u003c\/li\u003e\n\u003cli\u003eIndustrial control-panel and equipment maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt; margin: 20px 0 10px 0;\"\u003eIncluded Components\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0; padding-left: 22px;\"\u003e\n\u003cli\u003eUNI-T UT216C True RMS AC\/DC clamp meter\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003ePoint-contact temperature probe\u003c\/li\u003e\n\u003cli\u003e3 × 1.5V AAA batteries\u003c\/li\u003e\n\u003cli\u003eCarrying bag and user documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"UT216C","offer_id":58761605972293,"sku":"003121","price":97.47,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/1437ea81-8a0e-44a7-95c3-062a4fae849c.jpg?v=1785826709"},{"product_id":"uni-t-ut219e-600a-true-rms-ac-clamp-meter","title":"UNI-T True RMS AC Clamp Meter, 600 A, CAT IV 600 V, IP54 – UT219E","description":"\u003cp\u003eThe UNI-T UT219E is a rugged 600 A True RMS AC clamp meter designed for industrial electrical and HVAC maintenance. Its 33 mm jaw, LoZ voltage function, IP54 enclosure and CAT IV 600 V rating support professional troubleshooting in demanding environments.\u003c\/p\u003e\n\u003cdiv style=\"font-family: Helvetica, Arial, sans-serif; font-size: 12pt; color: #000000; line-height: 1.5;\"\u003e\n\u003ch2 style=\"font-size: 14pt;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e600 A AC Current Measurement:\u003c\/strong\u003e Measures AC current without disconnecting the conductor from the circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS Performance:\u003c\/strong\u003e Supports reliable measurement of non-linear AC voltage and current signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1000 V Voltage Measurement:\u003c\/strong\u003e Measures both AC and DC voltage up to 1000 V using the supplied test leads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoZ Voltage Mode:\u003c\/strong\u003e Low-impedance AC voltage measurement helps identify and suppress misleading ghost voltages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Protection:\u003c\/strong\u003e IP54 rated, tested for 2 m drops and compliant with CAT IV 600 V measurement environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt;\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 12pt;\" border=\"1\" cellspacing=\"0\" cellpadding=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f5f5f5;\"\u003e\n\u003cth style=\"text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUT219E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e6000-count LCD with 31-segment analogue bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current\u003c\/td\u003e\n\u003ctd\u003e60 A \/ 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum AC Current\u003c\/td\u003e\n\u003ctd\u003e600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current\u003c\/td\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoZ AC Voltage\u003c\/td\u003e\n\u003ctd\u003eUp to 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003eUp to 60 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003eUp to 60 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e10 Hz–10 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003e0.1%–99.9%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Frequency Response\u003c\/td\u003e\n\u003ctd\u003e40–400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw Opening\u003c\/td\u003e\n\u003ctd\u003e33 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Functions\u003c\/td\u003e\n\u003ctd\u003eAuto\/manual range, MAX\/MIN, relative mode, ZERO mode, data hold, diode test, continuity buzzer, flashlight, automatic backlight and auto power-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop Resistance\u003c\/td\u003e\n\u003ctd\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Category\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA, cETLus and GS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e3 × 1.5 V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e234.6 × 82 × 47 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e310 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 14pt;\"\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial AC current and voltage measurement\u003c\/li\u003e\n\u003cli\u003eElectrical distribution and equipment maintenance\u003c\/li\u003e\n\u003cli\u003eHVAC installation, inspection and troubleshooting\u003c\/li\u003e\n\u003cli\u003eCommercial facilities, factory equipment and field-service work\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 14pt;\"\u003eIncluded Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × UNI-T UT219E clamp meter\u003c\/li\u003e\n\u003cli\u003e1 × Set of test leads\u003c\/li\u003e\n\u003cli\u003e3 × 1.5 V AAA batteries\u003c\/li\u003e\n\u003cli\u003e1 × Carrying bag\u003c\/li\u003e\n\u003cli\u003e1 × English user manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"UT219E","offer_id":58783271289157,"sku":"003140","price":100.06,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/5a39641a-1453-48ad-ad57-fa5bfa8e6b2c.jpg?v=1785999683"},{"product_id":"uni-t-ut200a-200a-ac-clamp-meter","title":"UNI-T AC Clamp Meter, 200 A, 600 V, 2000-Count – UT200A","description":"\u003cp\u003eThe UNI-T UT200A is an AC clamp meter for measuring AC current up to 200A, AC\/DC voltage up to 600V and resistance up to 20kΩ. It features diode testing, continuity buzzer, manual ranging, data hold and LCD backlight for electrical maintenance and troubleshooting.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC current measurement up to 200A\u003c\/li\u003e\n\u003cli\u003eAC and DC voltage measurement up to 600V\u003c\/li\u003e\n\u003cli\u003e28mm jaw opening for non-invasive current measurement\u003c\/li\u003e\n\u003cli\u003eDiode test and continuity buzzer functions\u003c\/li\u003e\n\u003cli\u003eManual range selection, data hold, low-battery indication and LCD backlight\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eAC Clamp Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eUT200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay Count\u003c\/th\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eJaw Opening\u003c\/th\u003e\n\u003ctd\u003e28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC Current Range\u003c\/th\u003e\n\u003ctd\u003e2A \/ 20A \/ 200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC Current Accuracy\u003c\/th\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC Voltage Range\u003c\/th\u003e\n\u003ctd\u003e600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC Voltage Accuracy\u003c\/th\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Voltage Range\u003c\/th\u003e\n\u003ctd\u003e600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Voltage Accuracy\u003c\/th\u003e\n\u003ctd\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance Range\u003c\/th\u003e\n\u003ctd\u003e20kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance Accuracy\u003c\/th\u003e\n\u003ctd\u003e±(1% + 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Impedance\u003c\/th\u003e\n\u003ctd\u003e≥10MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003e9V battery (6F22)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLCD Size\u003c\/th\u003e\n\u003ctd\u003e35.6 × 18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Dimensions\u003c\/th\u003e\n\u003ctd\u003e208 × 76 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNet Weight\u003c\/th\u003e\n\u003ctd\u003e260 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHousehold electrical equipment maintenance\u003c\/li\u003e\n\u003cli\u003eAC circuit current checks\u003c\/li\u003e\n\u003cli\u003eElectrical voltage and resistance testing\u003c\/li\u003e\n\u003cli\u003eContinuity and diode checks\u003c\/li\u003e\n\u003cli\u003eElectrician workshop and field troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIncluded Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUT200A AC clamp meter\u003c\/li\u003e\n\u003cli\u003eTest probes\u003c\/li\u003e\n\u003cli\u003e9V battery\u003c\/li\u003e\n\u003cli\u003eCarrying bag\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"UNI-T","offers":[{"title":"UT200A","offer_id":58854977044805,"sku":"003153","price":18.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/7b10fbb5-8201-4f67-9345-435361d9e62e.jpg?v=1786589086"},{"product_id":"uni-t-ut202f-true-rms-ac-clamp-meter-600a","title":"UNI-T True RMS AC Clamp Meter, 600 A, 60 mF Capacitance \u0026 NCV – UT202F","description":"\u003cp\u003eThe UNI-T UT202F is a True RMS AC clamp meter for measuring AC current up to 600A, AC\/DC voltage up to 600V, resistance, capacitance, and frequency. NCV detection, continuity and diode testing, MAX\/MIN, relative mode, data hold, and backlighting support electrical maintenance, HVAC, industrial, and residential applications.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS AC current measurement up to 600A\u003c\/li\u003e\n\u003cli\u003eAC\/DC voltage measurement up to 600V\u003c\/li\u003e\n\u003cli\u003eNCV non-contact voltage detection\u003c\/li\u003e\n\u003cli\u003e60mF capacitance measurement range\u003c\/li\u003e\n\u003cli\u003e6000-count LCD with backlight\u003c\/li\u003e\n\u003cli\u003eContinuity and diode testing\u003c\/li\u003e\n\u003cli\u003eMAX\/MIN, relative mode, and data hold\u003c\/li\u003e\n\u003cli\u003e28mm jaw opening with auto-ranging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eUT202F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eTrue RMS AC Clamp Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e6000 counts; 37mm × 25mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eJaw Opening\u003c\/th\u003e\n\u003ctd\u003e28mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Rating\u003c\/th\u003e\n\u003ctd\u003eEN61010-2010; CAT II 600V \/ CAT III 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003e1.5V batteries × 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e215mm × 63mm × 36mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNet Weight\u003c\/th\u003e\n\u003ctd\u003e248g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eMeasurement Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current\u003c\/td\u003e\n\u003ctd\u003e0.06–600A\u003c\/td\u003e\n\u003ctd\u003e±(2% + 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current Frequency\u003c\/td\u003e\n\u003ctd\u003e50–100Hz\u003c\/td\u003e\n\u003ctd\u003e±(1% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003e600V\u003c\/td\u003e\n\u003ctd\u003e±(0.8% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003e600V\u003c\/td\u003e\n\u003ctd\u003e±(0.5% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Frequency\u003c\/td\u003e\n\u003ctd\u003e10Hz–10kHz\u003c\/td\u003e\n\u003ctd\u003e±(1% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e60MΩ\u003c\/td\u003e\n\u003ctd\u003e±(0.8% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e60mF\u003c\/td\u003e\n\u003ctd\u003e±(4% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e10Hz–10MHz\u003c\/td\u003e\n\u003ctd\u003e±(1% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial electrical maintenance\u003c\/li\u003e\n\u003cli\u003eResidential electrical troubleshooting\u003c\/li\u003e\n\u003cli\u003eHVAC and air-conditioning service\u003c\/li\u003e\n\u003cli\u003eAutomotive electrical inspection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIncluded Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUT202F clamp meter\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003e1.5V batteries × 2\u003c\/li\u003e\n\u003cli\u003eCarrying bag\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"UNI-T","offers":[{"title":"UT202F","offer_id":58860274221381,"sku":"003182","price":24.71,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/84bf86fa-2102-4547-8570-49f13779e04d.jpg?v=1786610684"},{"product_id":"uni-t-ut202r-true-rms-ac-clamp-meter-400a","title":"UNI-T True RMS AC Clamp Meter, 400A, Temperature Measurement \u0026 NCV – UT202R","description":"\u003cp\u003eThe UNI-T UT202R is a True RMS AC clamp meter for measuring AC current up to 400A and AC\/DC voltage up to 600V. It also provides resistance, capacitance, temperature, NCV, continuity, and diode testing for electrical maintenance and troubleshooting.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS AC current measurement up to 400A\u003c\/li\u003e\n\u003cli\u003eAC\/DC voltage measurement up to 600V\u003c\/li\u003e\n\u003cli\u003eResistance, capacitance, and temperature measurement\u003c\/li\u003e\n\u003cli\u003eNCV non-contact voltage detection\u003c\/li\u003e\n\u003cli\u003e4000-count LCD with backlight\u003c\/li\u003e\n\u003cli\u003eContinuity and diode testing\u003c\/li\u003e\n\u003cli\u003eMAX\/MIN, relative mode, and data hold\u003c\/li\u003e\n\u003cli\u003e28mm jaw opening with auto-ranging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eUT202R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eTrue RMS AC Clamp Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e4000 counts; 37mm × 25mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eJaw Opening\u003c\/th\u003e\n\u003ctd\u003e28mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Rating\u003c\/th\u003e\n\u003ctd\u003eCAT II 600V \/ CAT III 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003e1.5V R03 batteries × 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e215mm × 63mm × 36mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNet Weight\u003c\/th\u003e\n\u003ctd\u003eApprox. 248g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCE, UKCA, cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eMeasurement Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current\u003c\/td\u003e\n\u003ctd\u003e0.04–400A\u003c\/td\u003e\n\u003ctd\u003e±(2% + 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current Frequency\u003c\/td\u003e\n\u003ctd\u003e50–100Hz\u003c\/td\u003e\n\u003ctd\u003e±(1% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003e600V\u003c\/td\u003e\n\u003ctd\u003e±(0.8% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003e600V\u003c\/td\u003e\n\u003ctd\u003e±(0.5% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Frequency\u003c\/td\u003e\n\u003ctd\u003e10Hz–10kHz\u003c\/td\u003e\n\u003ctd\u003e±(1% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e60MΩ\u003c\/td\u003e\n\u003ctd\u003e±(0.8% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e4mF\u003c\/td\u003e\n\u003ctd\u003e±(4% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-40°C–1000°C\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial electrical maintenance\u003c\/li\u003e\n\u003cli\u003eResidential electrical troubleshooting\u003c\/li\u003e\n\u003cli\u003eHVAC and air-conditioning service\u003c\/li\u003e\n\u003cli\u003eAutomotive electrical inspection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIncluded Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUT202R clamp meter\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eTemperature probe\u003c\/li\u003e\n\u003cli\u003e1.5V R03 batteries × 2\u003c\/li\u003e\n\u003cli\u003eCarrying bag\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"UNI-T","offers":[{"title":"UT202R","offer_id":58863243690309,"sku":"003186","price":28.12,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/4325f628-e2c0-429b-9388-38516bc99a64.jpg?v=1786614195"},{"product_id":"uni-t-ut256-60a-ac-dc-fork-meter","title":"UNI-T AC\/DC Fork Meter, 60 A, True RMS \u0026 NCV – UT256","description":"\u003cp\u003eThe UNI-T UT256 is a compact True RMS fork meter designed to measure AC and DC currents up to 60A without opening the circuit. Its 10mm open-jaw design, NCV detection and audible and visual alerts make it suitable for fast testing in confined electrical installations.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC Current Testing\u003c\/strong\u003e – Measures alternating and direct current up to 60A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen-Jaw Design\u003c\/strong\u003e – Enables quick current testing without opening the circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS Measurement\u003c\/strong\u003e – Provides reliable AC current readings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10mm Fork Opening\u003c\/strong\u003e – Fits individual conductors in confined spaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNCV Detection\u003c\/strong\u003e – Detects nearby AC voltage without direct contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAudible and Visual Alerts\u003c\/strong\u003e – Provides clear NCV warning indications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUseful Test Functions\u003c\/strong\u003e – Includes hold, relative and zero modes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Construction\u003c\/strong\u003e – CAT III 600V rated and tested against 1m drops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUNI-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUT256\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue RMS AC\/DC Fork Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0A to 60.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0A to 60.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC\/DC Current Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(2% + 10) from 1.0A to 3.0A; ±(2% + 5) from 3.0A to 60.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Current Frequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50Hz to 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFork Opening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-Contact Voltage Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, with audible and visual alerts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomatic Power Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 30 minutes; function can be disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrop Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 × 1.5V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e171 × 42 × 28mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 120g including batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Colour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed and grey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA and cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFunctions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC and DC current measurement\u003c\/li\u003e\n\u003cli\u003eTrue RMS AC measurement\u003c\/li\u003e\n\u003cli\u003eNon-contact voltage detection\u003c\/li\u003e\n\u003cli\u003eAudible and visual NCV alerts\u003c\/li\u003e\n\u003cli\u003eData hold\u003c\/li\u003e\n\u003cli\u003eRelative-value measurement\u003c\/li\u003e\n\u003cli\u003eDC current zero adjustment\u003c\/li\u003e\n\u003cli\u003eLCD backlight\u003c\/li\u003e\n\u003cli\u003eLow-battery indication\u003c\/li\u003e\n\u003cli\u003eSelectable automatic power-off function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical panel inspection\u003c\/li\u003e\n\u003cli\u003eIndividual conductor current testing\u003c\/li\u003e\n\u003cli\u003eAutomotive electrical diagnostics\u003c\/li\u003e\n\u003cli\u003eIndustrial equipment maintenance\u003c\/li\u003e\n\u003cli\u003eResidential and commercial electrical servicing\u003c\/li\u003e\n\u003cli\u003eCurrent measurement in narrow spaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIncluded Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUNI-T UT256 fork meter\u003c\/li\u003e\n\u003cli\u003e2 × 1.5V AAA batteries\u003c\/li\u003e\n\u003cli\u003eWrist strap\u003c\/li\u003e\n\u003cli\u003eCarrying bag\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The NCV function detects the presence of AC voltage but does not provide a numerical voltage measurement. The UT256 has no test-lead voltage input.\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"UT256","offer_id":58873803374917,"sku":"003208","price":27.59,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/7e62c3bd-2334-484e-953b-10b40700d268.jpg?v=1786677919"},{"product_id":"uni-t-ut202t-600a-ac-clamp-meter","title":"UNI-T AC Clamp Meter, 600 A, 600 V, True RMS \u0026 NCV – UT202T","description":"\u003cp\u003eThe UNI-T UT202T is a 9999-count True RMS clamp meter for measuring AC current up to 600A and AC\/DC voltage up to 600V. Its automatic measurement, dual display, NCV detection and CAT III 600V rating support routine electrical installation and maintenance work.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC current measurement – Measures up to 600A\u003c\/li\u003e\n\u003cli\u003eTrue RMS readings – Supports accurate AC measurements\u003c\/li\u003e\n\u003cli\u003eSmart operation – Automatically detects common parameters\u003c\/li\u003e\n\u003cli\u003eDual display – Shows V+Hz or A+Hz simultaneously\u003c\/li\u003e\n\u003cli\u003eNCV detection – Identifies nearby AC voltage without contact\u003c\/li\u003e\n\u003cli\u003e9999-count display – Provides clear measurement resolution\u003c\/li\u003e\n\u003cli\u003eOne-hand design – Simplifies operation in the field\u003c\/li\u003e\n\u003cli\u003eBuilt-in lighting – Includes display backlight and flashlight\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eUNI-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUT202T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSmart AC Clamp Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Method\u003c\/td\u003e\n\u003ctd\u003eTrue RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Count\u003c\/td\u003e\n\u003ctd\u003e9999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange Selection\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDual Display\u003c\/td\u003e\n\u003ctd\u003eV+Hz \/ A+Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw Opening\u003c\/td\u003e\n\u003ctd\u003e28mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNCV Detection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Test\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible and Visual Indication\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd\u003eApproximately 15 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Functions\u003c\/td\u003e\n\u003ctd\u003eLow-battery indication, backlight and flashlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e2 × 1.5V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Colour\u003c\/td\u003e\n\u003ctd\u003eRed and grey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e201.5 × 47 × 28mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e241g, including batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificates\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA, cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eMeasurement Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current\u003c\/td\u003e\n\u003ctd\u003eUp to 600A\u003c\/td\u003e\n\u003ctd\u003e±(2.5%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003eUp to 600V\u003c\/td\u003e\n\u003ctd\u003e±(0.8%+3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003eUp to 600V\u003c\/td\u003e\n\u003ctd\u003e±(0.5%+3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003eUp to 6MΩ\u003c\/td\u003e\n\u003ctd\u003e±(0.8%+3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003eUp to 100mF\u003c\/td\u003e\n\u003ctd\u003e±(4%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e40–1000Hz\u003c\/td\u003e\n\u003ctd\u003e±(1.0%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical installation and commissioning\u003c\/li\u003e\n\u003cli\u003eDistribution-panel current checks\u003c\/li\u003e\n\u003cli\u003eMotor and equipment maintenance\u003c\/li\u003e\n\u003cli\u003eHVAC electrical-system diagnostics\u003c\/li\u003e\n\u003cli\u003eGeneral voltage and continuity troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIncluded Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUNI-T UT202T AC Clamp Meter\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003e2 × AAA batteries\u003c\/li\u003e\n\u003cli\u003eCarrying bag\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"UNI-T","offers":[{"title":"UT202T","offer_id":58873804161349,"sku":"003203","price":31.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/f38d1bf1-fb3d-4254-ada6-f2ca7e96668f.jpg?v=1786677940"},{"product_id":"uni-t-ut211b-true-rms-ac-dc-clamp-meter","title":"UNI-T Mini AC\/DC Clamp Meter, 60 A, True RMS \u0026 NCV – UT211B","description":"\u003cp\u003eThe UNI-T UT211B is a compact True RMS clamp meter for measuring AC and DC current up to 60 A with AC current resolution down to 0.1 mA. Its 17 mm jaw, VFC filter, NCV detection and multimeter functions suit automotive, battery, electronics and low-current troubleshooting.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e60 A AC\/DC Measurement\u003c\/strong\u003e – Measures both alternating and direct current without disconnecting the conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current Resolution\u003c\/strong\u003e – Provides AC current resolution down to 0.1 mA for low-current diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS Performance\u003c\/strong\u003e – Improves AC measurements on non-sinusoidal electrical signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVFC and NCV Functions\u003c\/strong\u003e – Filters high-frequency interference and detects nearby AC voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact 17 mm Jaw\u003c\/strong\u003e – Reaches conductors in confined panels, electronic equipment and vehicle systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eUNI-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eUT211B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eTrue RMS AC\/DC Clamp Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay Count\u003c\/th\u003e\n\u003ctd\u003e6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRanging\u003c\/th\u003e\n\u003ctd\u003eAuto range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC Measurement\u003c\/th\u003e\n\u003ctd\u003eTrue RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eJaw Opening\u003c\/th\u003e\n\u003ctd\u003e17 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecial Functions\u003c\/th\u003e\n\u003ctd\u003eVFC low-pass filter, NCV detection and Zero mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional Functions\u003c\/th\u003e\n\u003ctd\u003eDiode test, continuity buzzer, data hold and LCD backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuto Power Off\u003c\/th\u003e\n\u003ctd\u003eApproximately 15 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Voltage Input Impedance\u003c\/th\u003e\n\u003ctd\u003e≥10 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Category\u003c\/th\u003e\n\u003ctd\u003eCAT II 600 V \/ CAT III 300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCE, UKCA and cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay Size\u003c\/th\u003e\n\u003ctd\u003e39.3 × 26.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003e2 × 1.5 V R03\/AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e175 × 60 × 33.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNet Weight\u003c\/th\u003e\n\u003ctd\u003e170 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eMeasurement Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAC Current\u003c\/th\u003e\n\u003ctd\u003e600 mA \/ 6000 mA \/ 60 A; ±(1.5% + 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum AC Current Resolution\u003c\/th\u003e\n\u003ctd\u003e0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Current\u003c\/th\u003e\n\u003ctd\u003e6000 mA \/ 60 A; ±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum DC Current Resolution\u003c\/th\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC Voltage\u003c\/th\u003e\n\u003ctd\u003eUp to 600 V; ±(0.8% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Voltage\u003c\/th\u003e\n\u003ctd\u003eUp to 600 V; ±(0.7% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance\u003c\/th\u003e\n\u003ctd\u003eUp to 60 MΩ; ±(0.8% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCapacitance\u003c\/th\u003e\n\u003ctd\u003eUp to 62 mF; ±(4% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiode Test Voltage\u003c\/th\u003e\n\u003ctd\u003eApproximately 3.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAutomotive battery and parasitic-current testing\u003c\/li\u003e\n\u003cli\u003eElectric vehicle and battery-system diagnostics\u003c\/li\u003e\n\u003cli\u003eSolar power and low-voltage DC system inspection\u003c\/li\u003e\n\u003cli\u003eElectronic equipment troubleshooting\u003c\/li\u003e\n\u003cli\u003eControl circuit and confined-panel measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIncluded Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × UNI-T UT211B AC\/DC Clamp Meter\u003c\/li\u003e\n\u003cli\u003e1 × Set of Test Leads\u003c\/li\u003e\n\u003cli\u003e2 × R03\/AAA Batteries\u003c\/li\u003e\n\u003cli\u003e1 × Carrying Bag\u003c\/li\u003e\n\u003cli\u003e1 × User Manual\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"UNI-T","offers":[{"title":"UT211B","offer_id":58874975191365,"sku":"003225","price":112.18,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/c5f866f1-c275-496b-b04a-0f7e0d93fcc2.jpg?v=1786688054"},{"product_id":"uni-t-ut219m-true-rms-ac-clamp-meter","title":"UNI-T AC Clamp Meter, 600 A, True RMS \u0026 Temperature – UT219M","description":"\u003cp\u003eThe UNI-T UT219M is a 6000-count True RMS clamp meter for measuring up to 600 A AC current, 1000 V AC\/DC voltage, microcurrent, resistance, capacitance, frequency and temperature. Its IP54 housing, 2 m drop resistance and CAT III 1000 V \/ CAT IV 600 V rating make it suitable for industrial electrical, HVAC and motor maintenance.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e600 A True RMS Measurement\u003c\/strong\u003e – Accurately measures AC clamp current across non-linear electrical loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultifunction Testing\u003c\/strong\u003e – Measures voltage, microcurrent, resistance, capacitance, frequency and temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Phase Sequence Test\u003c\/strong\u003e – Checks the phase rotation of three-phase motors and electrical systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoZ Voltage Mode\u003c\/strong\u003e – Reduces false readings caused by ghost voltages in electrical circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Protection\u003c\/strong\u003e – Features IP54 protection, 2 m drop resistance and CAT IV 600 V safety classification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay Count\u003c\/th\u003e\n\u003ctd\u003e6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement Type\u003c\/th\u003e\n\u003ctd\u003eTrue RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClamp Current Type\u003c\/th\u003e\n\u003ctd\u003eAC only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eJaw Opening\u003c\/th\u003e\n\u003ctd\u003e33 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Impedance\u003c\/th\u003e\n\u003ctd\u003e≥10 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay Refresh Rate\u003c\/th\u003e\n\u003ctd\u003eApproximately 3 readings per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional Functions\u003c\/th\u003e\n\u003ctd\u003eMAX\/MIN, REL, data hold, zero mode, diode test, continuity test and automatic\/manual ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork Lights\u003c\/th\u003e\n\u003ctd\u003eAutomatic backlight and integrated flashlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIngress Protection\u003c\/th\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDrop Resistance\u003c\/th\u003e\n\u003ctd\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Category\u003c\/th\u003e\n\u003ctd\u003eCAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCE, UKCA, cETLus and GS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003e3 × 1.5 V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e234.6 × 82 × 47 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNet Weight\u003c\/th\u003e\n\u003ctd\u003e310 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eMeasurement Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Clamp Current\u003c\/td\u003e\n\u003ctd\u003e60 A \/ 600 A\u003c\/td\u003e\n\u003ctd\u003e±(1.8% + 6) at 40–100 Hz; ±(3.5% + 6) at 100–400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 V\u003c\/td\u003e\n\u003ctd\u003e±(0.6% + 3) at 6 V; ±(0.9% + 6) at higher ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 V\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoZ AC Voltage\u003c\/td\u003e\n\u003ctd\u003eUp to 600 V\u003c\/td\u003e\n\u003ctd\u003e±(2.5% + 6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Microcurrent\u003c\/td\u003e\n\u003ctd\u003eUp to 2000 μA\u003c\/td\u003e\n\u003ctd\u003e±(0.9% + 6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Microcurrent\u003c\/td\u003e\n\u003ctd\u003eUp to 2000 μA\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003eUp to 60 MΩ\u003c\/td\u003e\n\u003ctd\u003eRange dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003eUp to 60 mF\u003c\/td\u003e\n\u003ctd\u003eRange dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003eUp to 40 MHz\u003c\/td\u003e\n\u003ctd\u003e±(0.1% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 1000°C\u003c\/td\u003e\n\u003ctd\u003e±5°C at -40–0°C; ±(2.0% + 5°C) at 0–600°C; ±(2.5% + 5°C) at 600–1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThree-Phase Sequence\u003c\/td\u003e\n\u003ctd\u003e80–600 V AC\u003c\/td\u003e\n\u003ctd\u003e±(2.0% + 6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial electrical system inspection and maintenance\u003c\/li\u003e\n\u003cli\u003eHVAC and flame-sensor microcurrent testing\u003c\/li\u003e\n\u003cli\u003eThree-phase motor installation and phase-sequence checks\u003c\/li\u003e\n\u003cli\u003eCommercial building and field electrical troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIncluded Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUNI-T UT219M Clamp Meter\u003c\/li\u003e\n\u003cli\u003eTest Leads\u003c\/li\u003e\n\u003cli\u003ePoint-Contact Temperature Probe\u003c\/li\u003e\n\u003cli\u003e3 × AAA Batteries\u003c\/li\u003e\n\u003cli\u003eCarrying Bag\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"UNI-T","offers":[{"title":"UT219M","offer_id":58897569317189,"sku":"003250","price":116.81,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/files\/2ebedede-cb8a-40fd-a156-0223f11e5984.jpg?v=1786942593"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/0955\/9877\/collections\/2ebedede-cb8a-40fd-a156-0223f11e5984_5e908362-6e61-41a9-b600-04c8ba3749d0.jpg?v=1789306827","url":"https:\/\/www.periplusmro.com\/collections\/clamp-meters.oembed","provider":"PERIPLUS MRO SHOP","version":"1.0","type":"link"}